Product Description

BOURNS 2420-31-G 3 SERIES 5-PIN GAS DISCHARGE TUBE (GDT) PROTECTOR NEW BLACK GAS FUSE REPLACE 3B1E Features Superior protection at a low price Patented Switch-Grade Fail-Short Device Quick response and high energy handling Low capacitance (<2.5 pF) - ideal for high-speed networks in high exposure environments per UL497 (File E53117) Meets test requirements of Telcordia GR 974, GR1361, SBC SR 5165 and RUS PE-80 Solid brass, gold plated pins Test point access option Sealed option for harsh environments

The Bourns® 3-type 2420 overvoltage protection modules utilize Bourns’ propietary high-efficiency gas discharge tube with our patented Switch-Grade Fail-Short mechanism to provide robust and reliable surge and thermal overload protection at a very competitive price. The 2420 Series is based on Bourns’ three-terminal common chamber GDT. This design provides greatly improved and balanced turn-on characteristics for overvoltage protection.The GDT is UL approved for use without a back-up device. Air back-up devices can become contaminated; the circuitry of the 2420 eliminates this possibility. Our unique Switch-Grade Fail-Short device provides more reliable thermal overload protection compared to commonly used solder pellet or insulation burn-through designs. Bourns® 2420 Series 5-Pin protectors can be used universally for broadband voice and data circuits including ADSL, ADSL2+, VDSL ISDN and high-speed Ethernet. The 2420 Series is an economical, reliable and low capacitance choice for overvoltage protection of copper pair circuits.

Characteristics DC Breakdown 300-400 V AC Breakdown @ 60 Hz 300-400 V Impulse Breakdown 100 V/ƒÊs 625 V 1000 V/ƒÊs 875 V Insulation Resistance @ 100 Vdc >1 Gƒ¶ Insertion Loss @ 100 MHz ExceedsCategory 5 Return Loss @ 100 MHz Exceeds Category 5 Capacitance Tip to Ring @ 1 MHz <1.25 pF typical Capacitance Tip or Ring to Ground @ 1 MHz <2.50 pF typical Impulse Reset1 52 V, 260 mA <10 ms 135 V, 200 mA <10 ms 150 V, 200 mA <150 ms Impulse Life Characteristics (Tip and Ring to Ground Simultaneously) 10 A, 10/1000 ƒÊs >3000 operations 100 A, 10/1000 ƒÊs .......................................................................................................................... >300 operations 300 A, 10/1000 ƒÊs .......................................................................................................................... >100 operations 500 A, 10/1000 ƒÊs .......................................................................................................................... >400 operations2 2,000 A, 10/250 ƒÊs ......................................................................................................................... >25 operations 5,000 A, 20/100 ƒÊs ......................................................................................................................... >2 operations 20,000 A, 8/20 ƒÊs ........................................................................................................................... >1 operation AC Life Characteristics (Tip and Ring to Ground Simultaneously) 0.5 A rms continuous ..................................................................................................................... >30 seconds 1 A rms, 1 second, 600 ft. cable .................................................................................................... >60 operations 1 A rms, 1 second, 1 mile cable ..................................................................................................... >60 operations 10 A rms, 1 second ........................................................................................................................ >5 operations 65 A rms, 11 cycles ........................................................................................................................ >1 operation2 120 A rms, 0.1 second ................................................................................................................... 1 operation High Current Capability and Thermal Operation (Tip and Ring to Ground Simultaneously) ............... >30 A rms, 15 min. Storage and Operating Temperature .................................................................................................. -55 to +85 ‹C The BournsR 3-type 2420 overvoltage protection modules utilize Bournsf propietary high-efficiency gas discharge tube with our patented Switch-Grade Fail-Short mechanism to provide robust and reliable surge and thermal overload protection at a very competitive price. The 2420 Series is based on Bournsf three-terminal common chamber GDT. This design provides greatly improved and balanced turn-on characteristics for overvoltage protection.The GDT is UL approved for use without a back-up device. Air back-up devices can become contaminated; the circuitry of the 2420 eliminates this possibility. Our unique Switch-Grade Fail-Short device provides more reliable thermal overload protection compared to commonly used solder pellet or insulation burn-through designs. BournsR 2420 Series 5-Pin protectors can be used universally for broadband voice and data circuits including ADSL, ADSL2+, VDSL ISDN and high-speed Ethernet. The 2420 Series is an economical, reliable and low capacitance choice for overvoltage protection of copper pair circuits. REV. G 08/07 Meets test requirements of Telcordia GR 974, GR1361, SBC SR 5165 and RUS PE-80 Solid brass, gold plated pins Test point access option Sealed option for harsh environments Telcordia analyzed for controlled (non-sealed) and uncontrolled, high-exposure (sealed) environments per GR 974 and SBC SR 5165. Telcordia Technical Analysis Report DA-1597. Notes: 1 Network applied 2 Per RUS PE-80

How To Order Model Number Designator 2420 - X XX - X - XX

Module Length 3 = Standard: 52.37 mm (2.06 in.) 7 = Special Short: 41.19 mm (1.62 in.)

Housing Color/Circuit Type 1 = Black/Standard 6 = Blue/Standard 10 = Yellow/Standard 3 = Red/Special 9 = Orange/Standard Service (non-Bridgelifter)

Pin Plating G = Gold Plated N = Tin Plated

Special Options S = Sealed Case T = Test Points ST = Sealed Case and Test Points

Examples: 3B1E = 2420-31-G (black, no test points) 3C1E = 2420-31-G-T (black, with test points) 3B3E = 2420-33-G (red, no test points) 3C3E = 2420-33-G-T (red, with test points)