Klein 1684-74 ChicagoŽ Grip For Ehs Cable, Curved Jaw 47172-8 Upc 092644471728 New
Available*
Item # 30045000
Model # 47172-8
$438.21

* Notes on Availability:
If item is in stock, it will ship same day.
Lead times vary, contact us for more info.
(Images may not be of the actual item being sold.)
- Product Description
- You Might Also like
- Recently Viewed
Generic
Class
Group
Type
Manufacturer
LOT
Grips
Tools
Line Construction- Placing
Grips- Strand- Lashing Wire
Klein Tools

Product Description
Klein 1684-74 ChicagoŽ Grip For Ehs Cable, Curved Jaw 47172-8 Upc 092644471728 New
Klein 1684-74 ChicagoŽ Grip For Ehs Cable, Curved Jaw 47172-8 New Upc 092644471728
P/N 1684-74 ChicagoŽ Grip For Ehs Cable, Curved Jaw 47172-8 Upc 092644471728
When Pulling Ehs (Extra-High-Strength) Galvanized-Steel Cable, The Galvanizing Has A Tendency To Coat The Jaws Of Any Grip, Causing The Cable To Slip To Reduce The Possibility Of Slippage And Damage To The Cable, The Jaws Of This Grip Are Milled On A Curve With A Double V Contour For Use On Aluminum, Copper, Weatherproof Coated Wire, Pvc Covered Conductors And Messenger And Guy Strand Locking Handle Keeps Jaw Open While Grip Is Placed On Cable With A Hot Stick Made In Usa
Designed For Use On Aluminum, Copper, Weatherproof Coated Wire, Pvc Covered Conductors And Messenger And Guy Strand. The Chicago Style Grip Was Designed For Cable Sizes From 0.12-Inch To 1.0-Inch (3.10 To 25.4 Mm). When Pulling Ehs (Extra-High-Strength) Galvanized-Steel Cable, The Galvanizing Has A Tendency To Coat The Jaws Of Any Grip, Causing The Cable To Slip. Double V Contour Reduces The Possibility Of Slippage And Damage To The Cable.
Specifications Type: Chicago Grip Cable Type: Aircraft, Ehs, Messenger, Guy Strand Cable Diameter: 0.218'' To 0.55'' (5.54 To 13.97 Mm) Hot Latch: N Swing Latch: N Spring: Y Locking Handle: Y Jaw Type: Double V, Milled Curved Jaw Length: 5'' (12.7 Cm) Maximum Safe Load: 8000 Lb (3629 Kg) Weight: 5.6 Lb (2.6 Kg) Upc: 092644471728
Warnings Before Each Use, Clean Jaw Area And Inspect Grip For Proper Operation To Avoid Slippage. When Used On/Near Energized Lines, Ground, Insulate, Or Isolate Grip Before Pulling. Do Not Exceed Rated Capacity. Always Match Proper Size And Type Of Grip To Application. Grips Are To Be Used For Temporary Installation, Not For Permanent Anchorage.
Klein 1684-74 ChicagoŽ Grip For Ehs Cable, Curved Jaw 47172-8 New Upc 092644471728
P/N 1684-74 ChicagoŽ Grip For Ehs Cable, Curved Jaw 47172-8 Upc 092644471728
When Pulling Ehs (Extra-High-Strength) Galvanized-Steel Cable, The Galvanizing Has A Tendency To Coat The Jaws Of Any Grip, Causing The Cable To Slip To Reduce The Possibility Of Slippage And Damage To The Cable, The Jaws Of This Grip Are Milled On A Curve With A Double V Contour For Use On Aluminum, Copper, Weatherproof Coated Wire, Pvc Covered Conductors And Messenger And Guy Strand Locking Handle Keeps Jaw Open While Grip Is Placed On Cable With A Hot Stick Made In Usa
Designed For Use On Aluminum, Copper, Weatherproof Coated Wire, Pvc Covered Conductors And Messenger And Guy Strand. The Chicago Style Grip Was Designed For Cable Sizes From 0.12-Inch To 1.0-Inch (3.10 To 25.4 Mm). When Pulling Ehs (Extra-High-Strength) Galvanized-Steel Cable, The Galvanizing Has A Tendency To Coat The Jaws Of Any Grip, Causing The Cable To Slip. Double V Contour Reduces The Possibility Of Slippage And Damage To The Cable.
Specifications Type: Chicago Grip Cable Type: Aircraft, Ehs, Messenger, Guy Strand Cable Diameter: 0.218'' To 0.55'' (5.54 To 13.97 Mm) Hot Latch: N Swing Latch: N Spring: Y Locking Handle: Y Jaw Type: Double V, Milled Curved Jaw Length: 5'' (12.7 Cm) Maximum Safe Load: 8000 Lb (3629 Kg) Weight: 5.6 Lb (2.6 Kg) Upc: 092644471728
Warnings Before Each Use, Clean Jaw Area And Inspect Grip For Proper Operation To Avoid Slippage. When Used On/Near Energized Lines, Ground, Insulate, Or Isolate Grip Before Pulling. Do Not Exceed Rated Capacity. Always Match Proper Size And Type Of Grip To Application. Grips Are To Be Used For Temporary Installation, Not For Permanent Anchorage.